Network Working Group Bernard Cosell
RFC # 271 BBN
NIC 7819 3 January 1972
Categories: B.1
Updates: None
Obsoletes: None
IMP System Change Notification
------------------------------
We are planning to install a new version of the IMP System,
version 2514. The new version is scheduled for field installation
Thursday, January 13,
1972 between noon and 1 PM EST, and will require
the assistance of IMP-site personnel at each site.
There were two principal problems with version 2513, both related
to the delay inserted between the time when a Host comes up and the
time when its IMP will accept the second packet from the Host. The
first was that the delay was lengthened to slightly over 40 seconds,
which caused hardware difficulties for some Hosts. The second was
that there was an ambiguity that could make the delay run as long as a
minute and a quarter. On the first point, the delay has been backed
off from 40 seconds to 30 seconds, as it was for IMP systems prior to
2513. On the second point, the ambiguity has been entirely removed.
(Note, however, that BBN Report No. 1822, on page 23, specifies that
the delay may range from 30 to 90 seconds, and that future versions
may require a longer delay.)
In summary, a Host may come alive in one of two ways, corres-
ponding to the two ways in which the Host can go down. If the Host
went down voluntarily (by sending a "Host going down" to the IMP), the
Host indicates his intention to come alive by sending the IMP
something. If the Host went down involuntarily (by dropping his ready
line), the Host indicates his intention to come alive by bringing his
ready line back up. In either case